This unit has standard features to allow installation to be carried out with ease and accuracy. This includes an additional service valve allows for quicker commissioning and auto wiring corrections, saving time and money.
Allows for different temperatures in different rooms at the same time, delivering personalised comfort to those with differing preferences.
The outdoor capacities of this unit range from 5kW to 14kW. The 14kW can connect up to 5 heads through a single outdoor unit, allowing for energy and space savings.
Gold fin epoxy coated protection is standard on both indoor and outdoor coils as standard. This assists in the defrosting process and further reduces corrosion from extreme Australian conditions.
After a blackout as auto-restart function restarts the machine in its last programmed setting once power is restored, meaning the system does not have to be reprogrammed.
A range of indoor unit formats can be matched to this multi split system, including ducted, wall hung and mini-cassette.
Specification | 7.10 kW | 9.85 kW | 10.95 kW | 13.50 kW |
---|---|---|---|---|
Model Number - Indoor Unit | MRC-071AS-3 | MRC-100AS-4 | MRC-110AS-5 | MRC-135AS-5 |
Cooling Capacity (kW) | 7.10 | 9.85 | 10.95 | 13.50 |
Heating Capacity (kW) | 7.75 | 9.9 | 11.2 | 14.80 |
Outdoor Sound Level (H/SL) | 61 | 61 | 65 | 65 |
Indoor unit Dimensions (HxWxD) (mm) | 810 x 946 x 410 | 810 x 946 x 410 | 810 x 946 x 410 | 1333 x 952 x 415 |
* C = Cooling H = Heating
Operational manual and other product-related documents
Bought a ducted add on unit from Aircon Warehouse. It’s a 3 phase unit Model No. SCR203C. My old Brivis unit died, this replacement slotted in nicely, I had to make some adjustments with the ducting as the evap unit is wider and needed an adapter that AC W’house ordered for this model. Electrical was easy, switches the Gas heating or Air Con cooling via the existing 24v supply box mounted on my gas unit. Installed it and pumped out 3.6 degrees from the vents, super cool and about 1/10th the noise of my old Brivis unit, can’t believe I waited so long to install it. If I had to pick anything bad would be the weight of the outside unit 4 people needed and the copper on the outside unit goes through a plastic grommet that protects the pipes from wearing on the outside unit sheet metal entry point into it, obviously melts when welding the pipes. Best unit ever…………and saved my marriage by the way!!
I have only positive things to say about them.
Very good company to work with.