Can be retrofitted onto an existing R22 system by simply replacing both the indoor and outdoor units whilst retaining the field piping intact.
Can be installed quickly and easily, with minimal disruption to the building occupants. The units are compact and lightweight, significantly reducing constraints during carry-in.
Is equipped to handle both the coldest and warmest days of the year.
Up to 64 indoor units can be connected to a single system, which is significantly higher than other legacy systems.
System flushing and refrigerant charging are carried out with a single push of a button and combined with the automatic measurement of required refrigerant charge, this dramatically simplifies the testing and commissioning process when compared to conventional air systems.
Using the existing piping you can increase the cooling capacity output of your air conditioning system.
Specification | 14.1 kW | 22.5 kW | 28.2 kW | 33.7 kW | 40.2 kW | 45.3 W |
---|---|---|---|---|---|---|
Model Number - Outdoor Unit | RQYQ140PY1 | RQYQ8PY1B | RQYQ10PY1B | RQYQ12PY1B | RQYQ14PY1B | RQYQ16PY1B |
Cooling Capacity (kW) | 14.1 | 22.5 | 28.2 | 33.7 | 40.2 | 45.3 |
Heating Capacity (kW) | 16.0 | 25.0 | 31.5 | 37.5 | 45.0 | 50.0 |
Outdoor Sound Level (H/SL) | 54 | 57 | 58 | 60 | 60 | 60 |
Outdoor unit Dimensions (HxWxD) (mm) | 1680 x 635 x 765 | 1680 x 930 x 765 | 1680 x 930 x 765 | 1680 x 930 x 765 | 1680 x 1240 x 765 | 1680 x 1240 x 765 |
* C = Cooling H = Heating
Specification | 50.7 kW | 56.2 kW | 61.9 W | 67.4 W | 3.5 kW | 79.0 kW | 85.5 kW | 90.6 kW |
---|---|---|---|---|---|---|---|---|
Model Number - Outdoor Unit | RQYQ18PY1B Combination Units: RQYQ8PY1B RQYQ10PY1B | RQYQ20PY1B Combination Units: RQYQ8PY1B RQYQ12PY1B | RQYQ22PY1B Combination Units: RQYQ10PY1B RQYQ12PY1B | RQYQ24PY1B Combination Units: RQYQ12PY1B RQYQ12PY1B | RQYQ26PY1B Combination Units: RQYQ10PY1B RQYQ16PY1B | RQYQ28PY1B Combination Units: RQYQ12PY1B RQYQ16PY1B | RQYQ30PY1B Combination Units: RQYQ14PY1B RQYQ16PY1B | RQYQ32PY1B Combination Units: RQYQ16PY1B RQYQ16PY1B |
Cooling Capacity (kW) | 50.7 | 56.2 | 61.9 | 67.4 | 73.5 | 79.0 | 85.5 | 90.6 |
Heating Capacity (kW) | 56.5 | 62.5 | 69.0 | 75.0 | 81.5 | 87.5 | 95.0 | 100.0 |
Outdoor Sound Level (H/SL) | 61 | 62 | 63 | 63 | 63 | 63 | 63 | 63 |
Outdoor unit Dimensions (HxWxD) (mm) | (1680 x 930 x 765) + (1680 x 930 x 765) | (1680 x 930 x 765) + (1680 x 930 x 765) | (1680 x 930 x 765) + (1680 x 930 x 765) | (1680 x 930 x 765) + (1680 x 930 x 765) | (1680 x 930 x 765) + (1680 x 1240 x 765) | (1680 x 930 x 765) + (1680 x 1240 x 765) | (1680 x 1240 x 765) + (1680 x 1240 x 765) | (1680 x 1240 x 765) + (1680 x 1240 x 765) |
* C = Cooling H = Heating
Specification | 96.6 kW | 102 kW | 108 W | 113 W | 119 kW | 125 kW | 131 kW | 136 kW |
---|---|---|---|---|---|---|---|---|
Model Number - Outdoor Unit | RQYQ34PY1B Combination Units: RQYQ10PY1B RQYQ10PY1B RQYQ14PY1B | RQYQ36PY1B Combination Units: RQYQ10PY1B RQYQ10PY1B RQYQ16PY1B | RQYQ38PY1B Combination Units: RQYQ10PY1B RQYQ12PY1B RQYQ16PY1B | RQYQ40PY1B Combination Units: RQYQ12PY1B RQYQ12PY1B RQYQ16PY1B | RQYQ42PY1B Combination Units: RQYQ10PY1B RQYQ16PY1B RQYQ16PY1B | RQYQ44PY1B Combination Units: RQYQ12PY1B RQYQ16PY1B RQYQ16PY1B | RQYQ46PY1B Combination Units: RQYQ14PY1B RQYQ16PY1B RQYQ16PY1B | RQYQ48PY1B Combination RQYQ16PY1B RQYQ16PY1B RQYQ16PY1B |
Cooling Capacity (kW) | 96.6 | 102 | 108 | 113 | 119 | 125 | 131 | 136 |
Heating Capacity (kW) | 108 | 113 | 119 | 125 | 132 | 138 | 145 | 150 |
Outdoor Sound Level (H/SL) | 64 | 64 | 65 | 65 | 65 | 65 | 65 | 65 |
Outdoor unit Dimensions (HxWxD) (mm) | (1680 x 930 x 765) + (1680 x 930 x 765) + (1680 x 1240 x 765) | (1680 x 930 x 765) + (1680 x 930 x 765) + (1680 x 1240 x 765) | (1680 x 930 x 765) + (1680 x 930 x 765) + (1680 x 1240 x 765) | (1680 x 930 x 765) + (1680 x 930 x 765) + (1680 x 1240 x 765) | (1680 x 930 x 765) + (1680 x 1240 x 765) + (1680 x 1240 x 765) | (1680 x 930 x 765) + (1680 x 1240 x 765) + (1680 x 1240 x 765) | (1680 x 1240 x 765) + (1680 x 1240 x 765) + (1680 x 1240 x 765) | (1680 x 1240 x 765) + (1680 x 1240 x 765) + (1680 x 1240 x 765) |
* C = Cooling H = Heating
Specification | 50.7 kW | 56.2 kW | 61.9 W | 67.4 W | 73.5 kW | 79.0 kW |
---|---|---|---|---|---|---|
Model Number - Outdoor Unit | RQCEQ280PY1 Combination Units: RQEQ140PY1 RQEQ140PY1 | RQCEQ360PY1 Combination Units: RQEQ180PY1 RQEQ180PY1 | RQCEQ460PY1 Combination Units: RQEQ140PY1 RQEQ140PY1 RQEQ180PY1 | RQCEQ500PY1 Combination Units: RQEQ140PY1 RQEQ180PY1 RQEQ180PY1 | RQCEQ540PY1 Combination Units: RQEQ180PY1 RQEQ180PY1 RQEQ180PY1 | RQCEQ636PY1 Combination Units: RQEQ212PY1 RQEQ212PY1 RQEQ212PY1 |
Cooling Capacity (kW) | 28.2 | 36.3 | 46.3 | 50.4 | 54.4 | 64.0 |
Heating Capacity (kW) | 32.0 | 40.0 | 52.0 | 56.0 | 60.0 | 67.2 |
Outdoor Sound Level (H/SL) | 57 | 61 | 61 | 62 | 63 | 65 |
Outdoor unit Dimensions (HxWxD) (mm) | (1680 x 635 x 765) + (1680 x 635 x 765) | (1680 x 635 x 765) + (1680 x 635 x 765) | 1680 x 635 x 765) + (1680 x 635 x 765) + (1680 x 635 x 765) | 1680 x 635 x 765) + (1680 x 635 x 765) + (1680 x 635 x 765) | 1680 x 635 x 765) + (1680 x 635 x 765) + (1680 x 635 x 765) | 1680 x 635 x 765) + (1680 x 635 x 765) + (1680 x 635 x 765) |
* C = Cooling H = Heating
Specification | 71.7 kW | 74.9 kW | 82.2 kW | 85.4 W |
---|---|---|---|---|
Model Number - Outdoor Unit | RQCEQ712PY1 Combination Units: RQEQ140PY1 RQEQ180PY1 RQEQ180PY1 RQEQ212PY1 | RQCEQ744PY1 Combination Units: RQEQ140PY1 RQEQ180PY1 RQEQ212PY1 RQEQ212PY1 | RQCEQ816PY1 Combination Units: RQEQ180PY1 RQEQ212PY1 RQEQ212PY1 RQEQ212PY1 | RQCEQ848PY1 Combination Units: RQEQ212PY1 RQEQ212PY1 RQEQ212PY1 RQEQ212PY1 |
Cooling Capacity (kW) | 71.7 | 74.9 | 82.2 | 85.4 |
Heating Capacity (kW) | 78.4 | 80.8 | 87.2 | 89.6 |
89.6 Outdoor Sound Level (H/SL) | 64 | 65 | 66 | 66 |
Outdoor unit Dimensions (HxWxD) (mm) | (1680 x 635 x 765) + (1680 x 635 x 765) + (1680 x 635 x 765) + (1680 x 635 x 765) | (1680 x 635 x 765) + (1680 x 635 x 765) + (1680 x 635 x 765) + (1680 x 635 x 765) | (1680 x 635 x 765) + (1680 x 635 x 765) + (1680 x 635 x 765) + (1680 x 635 x 765) | (1680 x 635 x 765) + (1680 x 635 x 765) + (1680 x 635 x 765) + (1680 x 635 x 765) |
* C = Cooling H = Heating
Operational manual and other product-related documents
I installed the 3.5 kW Daikin US7 as a combined heater and cooler for my new living areas, because of its environmental credentials. I’ve only used it over the winter, so can only comment on its heating efficiency so far, but have found it to be extremely rapid to heat up a room, reasonably quiet in its operation, and definitely cheaper to run than my old ducted gas system. I like the “comfort” setting, so that for heating, the vents point downwards and don’t create too much of a breeze, and when cooling, they oscillate, to help cool further.
I love our Daikin ac and we have two. One in a bedroom and one in the main living area. Only had ducted before the split system and the Daikin is so efficient and in 40-degree Adelaide heat we stay nice and cool. Quite quiet – can watch TV and have conversation easily. Doesn’t run up a huge power bill even though we use it a lot. Very happy.
This air conditioner is saving me in the summer months. I can actually get a good sleep now that the house isn’t hot at night when I go to bed. It cools down the place very quickly. The only down side is that I can’t seem to get a good setting for when the house is already cool and I just want some circulation.