Error codes identify when something may need to be repaired or isn’t functioning properly. Each error code has a meaning to help you understand the problem and what needs to be done to fix it.
Below are the error codes for Braemar and the matching explanation.
Doing so will delete your air conditioner’s on board memory. We recommend trying this simple trouble-shooting solution before spending money on a service call.
Do so by separating your AC system from its power supply. Unplug it from a power point, turn off the isolator next to the outdoor unit or shut down your house’s power from the electrical board. Then leave it for 15 – 30 minutes.
Have an expert come out to look into your error. This is safer and will ensure you don’t accidentally cause further damage to your air con unit.
b5: Indoor unit liquid valve temperature sensor open/short circuited
b7: Indoor unit liquid valve temperature sensor open/short circuited
dn: Communication line misconnected or expansion valve error
En: Frequency restricted/reduced with IPM current protection
EU: Frequency restricted/reduced with IPM temperature protection
E1: Compressor high-pressure protection
E2: Indoor anti-freeze protection
E3: Compressor low-pressure protection
E4: Compressor high discharge temperature protection
E5: Whole unit over-current protection
E6: Communication error
E7: Running mode conflict
E8: Overload protection
E9: Indoor unit full water protection
Fo: Pump-down
FH: Frequency restricted/reduced with anti-freezing protection
F0: System charge shortage or blockage protection
F1: Return air temperature sensor open/short circuited
F2: Evaporator temperature sensor open/short circuited
F3: Outdoor ambient temperature sensor open/short circuited
F4: Outdoor mid-tube temperature sensor open/short circuited
F5: Discharge temperature sensor open/short circuited
F6: Frequency restricted/reduced with overload protection
F8: Frequency restricted/reduced with whole unit current protection
F9: Frequency restricted/reduced with high discharge temperature
Hc: Pfc protection
HE: Compressor demagnetization protection
H1: Forced defrosting
H3: Compressor overheating protection
H5: IPM current protection
H6: Motor stalling
H7: Compressor desynchronising protection
LA: Outdoor fan 1 error protection
Lc: Compressor Startup failure
Ld: Compressor phase loss/reversal protection
LE: Compressor stalling
LF: Over-Speeding
LP: Indoor and outdoor units unmatched
L3: Outdoor fan 1 error protection
L9: Over-power protection
Pd: Sensor connection protection
PE: Temperature drift protection
PF: Drive board temperature sensor error
PH: DC Bus over-voltage protection
PL: DC Bus under-voltage protection
PP: AC input voltage abnormal
PU: Capacitor charging error
P5: Over phase current protection
P6: Drive board communication error
P7: IPM temperature sensor open / short circuited
P8: IPM temperature protection
P9: AC contactor protection
U1: Compressor phase current sensing circuit error
U3: DC bus voltage drop error
U5: Whole unit current sensing circuit error
U7: 4 way valve reversing error
U8: PG motor zero-crossing protection
U9: Defrost or oil return
d1: DRED mode 1 (full shut down)
d2: DRED mode 2 (50% power)
d3: DRED mode 3 (75% power)